Author: Betul Onal Gunay (Turkey)
Co-authors: Irfan Akalin, Ahmet Kalkisim
Purpose
To investigate the impact of Beck Anxiety Inventory Score (BAIS) on choroidal thickness (CT) profile and to determine the use of BAIS to predict CT.
Setting/Venue
University of Health Sciences, Trabzon Kanuni Training and Research Hospital
Methods
Between December 2020 and March 2021, participants who underwent BAIS survey were included in the study. Demographic data along with blood pressure (BP) measurements, oxygen saturation and pulse measurements were noted. A comprehensive ophthalmic evaluation was done. Ocular biometry (LenStar LS 900, Haag Streit Diagnostics) was performed. Spectral domain optical coherence tomography (SD – OCT, Heidelberg, Germany) was used to analyse central macular thickness (CMT), retinal nerve fiber layer thickness (RNFLT) and ganglion cell layer thickness (GCLT). Enhanced depth imaging (EDI) OCT technique was used to evaluate CT with a manual caliper. The CT profile included central, nasal, temporal, superior and inferior CT with 1 mm and 2 mm distances away from central region. All measurements were performed at the same time period of the day (between 8.00 AM – 9.00 AM). Exclusion criteria were, any topical or systemic drug use, past ocular surgery and/or ocular trauma, any history of ocular and/or systemic disease and non – optimal OCT measurements.
Results
Totally 31 female and 17 male subjects with an average age of 39.6 ± 8.4 years were included in the study.Mean systolic and diastolic BPs were 104.3 ± 17.2 mmHg ; 70.5±10.2 mmHg,respectively.Mean pulse oxymetry was 98.1 ± 1.5 and pulse rate was 84.5 ± 13.1 per minute.The mean AL was 23.6 ± 0.8 mm.The mean BAIS was 8.9 ± 8.8 in the study.Mean CT was 333.5 ± 82.6 µm, 307.2 ± 83.1 µm, 256.9 ± 82.0 µm, 318.5 ± 80.4 µm, 293.2 ± 68.6 µm, 332.6 ± 71.6 µm, 329.4 ± 66.5 µm, 315.9 ± 76.6 µm and 305.1 ± 66.3µm, in central, nasal 1 mm, nasal 2 mm, temporal 1 mm, temporal 2 mm, superior 1 mm, superior 2 mm, inferior 1 mm, inferior 2 mm quadrants, respectively. No significant differences of CT were present between subjects with high BAIS and without high BAIS (p=0.35). There was no significant correlation between the BAI score and CMT, GCLT and RNFLT. In a multivariate regression model, as subfoveal CT a dependent variable ; age, gender, BMI, pulse rate , systolic and diastolic BPs, AL, BAIS were an independent variables, only AL had a significant association with subfoveal CT (p=0.007).
Conlusions
The BAIS may not be a significant predictor in CT evaluation.
Financial Disclosure
Authors have no financial relations with specific companies
Comments
-