Author: Karol Quintero-Lizcano (Colombia)
Co-authors: Karol Quintero-Lizcano, Carlos Mario Rangel-Gualdrón, Maria Isabel Corrales, Virgilio Galvis-Ramírez, Alejandro Tello-Hernandez
Purpose
The mainstay therapy of uveitic macular edema focuses in controlling inflammation, with topic, regional and systemic corticosteroids, and immunosuppressive drugs. Adjunctive regional corticosteroid treatment is critical for uveitic macular edema management and they can be delivered through different routes with similar efficacy, including dexamethasone sustained-release implants (Ozurdex®, Allergan, Dublin, Ireland)(1). In the literature different case series and retrospective studies of patients with bilateral uveitic macular edema with adequate response in both eyes to unilateral management with intravitreal antiangiogenics have been described. However, few reports have shown the effect of unilateral regional corticosteroids, such as intravitreal dexamethasone in cases of bilateral macular edema. Herein we describe a patient with bilateral non-infectious uveitic macular edema, who presented a good therapeutic response in both eyes following unilateral intravitreal dexamethasone implant injection.
Setting/Venue
This patient presented to our ophthalmology department in an ideal venue for resident education, as well as a complete ophthalmologic evaluation by our residents and attendings.
Methods
Case report of a 69-year-old male patient with bilateral recurrent non-infectious anterior uveitis managed with topical corticosteroids who presents to our clinic with blurred vision in both eyes. Cystoid macular oedema and bilateral subretinal fluid was documented (Figure 1). It was managed with unilateral intravitreal dexamethasone implant in the eye with less visual acuity. During follow-up patient initially rejected systemic management with immunomodulators.
Results
This patient received management with a unilateral dexamethasone intravitreal implant. After two months of follow-up, he presented an adequate therapeutic response in both eyes, reaching a better corrected visual acuity of 20/30 and 20/40 in his right and left eye respectively, additionally resolution of uveitic macular oedema was documented bilaterally in macular OCT (Figure 2).
Conlusions
Other reports have also shown the therapeutic effect of a single intravitreal dexamethasone implant in patients with bilateral edema of the macula (2,3). In a study in monkey eyes Chang-Lin et al. found that following intravitreal dexamethasone implant (Ozurdex®), the corticosteroid was detected in retina, vitreous and in plasma (4). This, coupled up with the increased ocular permeability in uveitic eyes associated to an active inflammatory state and the alteration of the blood-retina barrier could explain why intravitreal medication might be able to reach adequate concentrations in vitreous humor and have a clinical effect bilaterally in uveitic eyes even with unilateral treatment. Treating bilateral macular edema in the course of uveitic edema of the macula (non-infectious) with unilateral dexamethasone implant injections may have an advantageous role also in the fellow eye, if affected. Our findings, and those of other authors showing similar cases, may suggest that intravitreal drugs can reach systemic circulation and penetrate the fellow eye. This could be an initial approach in patients with bilateral macular edema, especially in those who face economic constrictions. However, further studies might be needed to confirm these findings.
Financial Disclosure
None of the authors have any conflicts of interests nor financial interests to declare.
Comments
-