Human amniotic membrane graft: The fastest solution to optic disc pit maculopathy
Author: Gagan Bhatia (India)
Co-authors: Daraius Shroff, Cyrus Shroff, Stuti Astir, Sandeep Kumar
Purpose
To demonstrate the technique and results of Human Amniotic Membrane Grafting in a case of optic disc pit.
Setting/Venue
A Tertiary care centre for ocular sciences
Methods
To illustrate the technique of Human amniotic membrane grafting with macular sparing ILM peel in a case of optic disc pit . OCT based measurement of the pit was done. A skin trephine was used to fashion the optimum graft size. Bimanual handling and placement leading to a good placement for closure of the pit .
Results
The case showed complete resolution of the NSD on post operative day 1. OCT based follow up along with microperitmery showed no reoccurance over the follow up period of 3 months.
Conlusions
Optic disc pit surgery has always been controversial with various techniques being described over the years. Persistent Fluid or late resolution and recurrences have lead to doubts on the perfect procedure for disc pits. Human Amniotic Membrane Grafting seems a promising solution, leading to a complete closure of the pit with fast and complete resolution of the NSD. This in turn lead to better Anatomical and Visual gain .