Author: Abner Grijalva Ferguson (Spain)
Co-authors: Rosa Coco
Purpose
Principal Objective The objective of this study is to describe the characteristics, outcomes and complications of eyes after vitreoretinal surgery using SO as endotamponade. Secondary Objective To compare the complication rates after vitreoretinal surgery using 1000- vs 5000-centistoke SO. There has been multiple based on literature search in other articles reporting complications and outcomes after the use of 1000 cSt SO. Nonetheless, based on a literature search of the MEDLINE database there has been limited number of published reports comparing the complications and outcomes rates after the use of 1000 cSt and 5000 cSt,. Most these studies includes a reduced sample size giving results which could not be statistically proven. Even though the Silicon Study group proved SO to be a very useful tool in the treatment of complicated retinal detachments, questions and indications for selecting SO viscosity for use in clinical settings still remains unanswered. Hence this warrants additional studies with a larger sample size, like this one, to compare and validate a true associations between complications and SO viscosity.
Setting/Venue
In this retrospective study, the records of 362 eyes undergoing PPV with injection of SO for complicated vitreoretinal conditions followed in the Hospital Universitario Valladolid (n=22) and the IOBA’s (n=340) vitreoretinal clinic and presenting between May 2006 and November 2019 were reviewed.
Methods
All eyes had a complete preoperative examination, including best corrected visual acuity (BCVA), IOP by applanation tonometry, biomicroscopic and fundus examination. Postoperative follow-up evaluations took place at 1week, 3, 6 and 12 months. At each follow-up visit, a complete ocular evaluation was performed, including BCVA, IOP, slit lamp and fundus examination. A database was created with multiple characteristics. These variables were subsequently analyzed. Comparison between complication rates when using SIOBAL 1000 cSt and 5000 cSt (AJL, Alava, Spain) was then performed. BCVA was measured using Snellen and ETDR charts and converted into logMAR units for statistical purposes. Ambulatory vision was defined as a BCVA of 4/200 (logMAR 1.7) or better. According to a modified scale of Avery and colleagues, non-numerical vision was arbitrarily assigned a logMAR value [counting fingers (CF) logMAR 2.0, hand motion (HM) logMAR 2.1, light perception (LP) logMAR 2.3, no light perception (NLP) logMAR 2.8]. Increase intraocular pressure above 28 mm Hg was categorized as Ocular hypertension. Besides, we defined hypotony as having IOP ≤5 mmHg, the same cut off as in the Silicone Study.
Results
Our study group included 230 patients [91 males (39.6 %), 138 females (60.4 %)]. Mean age was 58.2±18.4 years. Visual acuities (logMAR) were 1.8±0.6, and intraocular pressures (mmHg) were 15.6±7 at baseline, 15.7±6 at last follow-up.Mean residence time of SO in the eye was 9.109 ± 7.7068 months (median, 7 months, range 01-30 months). Ninety six (47.6%) surgeries were performed with SO 1000 cSt and one hundred thirty four (58.3%) using SO 5000 cSt. The indications for SO use included: previous re-RD (n=152); complicated primary RD (n=126); PDR (n=24); history of previous trauma, and/or intraocular foreign body and/or scleral rupture (n=19); and 28 surgeries had various etiologies including subretinal hemorrhage secondary to wet AMD, choroidal hemorrhage, Melanoma, CMV retinitis and Uveitis. The main silicone-oil-related complications observed were: SO emulsification 22.51%, redetachment 21.35%, ocular hypertension 19% of which 25% developed secondary glaucoma, band keratopathy 5.56%, hypotony 3.51%. Most of the complications, (45%) appeared < 4 months post-operative being acute ocular hypertension being the most common with a 14.86%.
Conlusions
This study provides evidence that there is a higher incidence of complications in the 1000 cSt group than in the 5000 cSt. Regardless, of our results the final visual outcome did not differ much but we must take into consideration that a higher rate of complications can result in recurrent visits to the hospital, more expenses, as well as additional nuisances to the patient therefore lower quality of life. There is much to be investigated for the predilection of SO used in surgery, there are not enough literature comparing this two SO.
Financial Disclosure
none
Comments
-